Server Technology C4G36RA-2CBE2FE2 PRO4X PDU 208 Volt 36 Outlets 0U
Loading...
Loading...
Authorized Server Technology Reseller
Direct from Server Technology - engineering & application support available
Loading...
Product Category
Power Distribution Units (PDUs)
Platform
PRO4X
Metering and Switching
Switched POPS
Total Outlets
36
Server Technology's PRO4X Switched POPS PDUs run on our state-of-the-art Xerus network interface platform and provide remote access to power, PDU status, input, outlet, and branch current monitoring, and outlet on/off control. The PDU features RamLock, a self-locking mechanism to prevent accidental cord disconnects, and our award-winning HDOT Cx outlets that can be deployed as either a C13 or C19. Switched POPS PDUs are secured with strong configurable password, active directory, 256-bit AES encryption, SSH, SSL, and HTTPS support. SNMP traps provide automated alerts on power and environmental conditions from Legrand's plug-and-play environmental monitoring sensors like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more.
HDOT Cx Outlet: Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
45 Degree Angled Infeed: The angled infeed improves accessibility, provides infeed strain relief, and its bend radius is suitable with 60A rated cords.
Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
Multi-Unit Linking & Cascading: Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
Multi-Color LCD: An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
Hot Swappable Controller: The Controller is the PDU's center of intelligence and housescomputing, display, and connectivity ports.
Power Quality Measurements: Monitor and alert on the power being fed to the PDU for harmonics, voltage dips and swells, crest factor, and more at the outlet or load.
RGB LED Outlet Indicators: RGB LEDs identify an outlet's on/off state, if it's above/below a certain power threshold, or if it's in suspect of a power measurement irregularity.
Waveform Capture: Capture voltage and current waveforms automatically or upon demand.
RamLock Locking Outlets: A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
Environmental Monitoring: Support up to 12 daisy-chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
Per- Inlet Power Sensing: PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
Per-Outlet Power Sensing: POPS® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
Branch Circuit Protection: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
Outlet Control: On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
Alternating-Phase Outlets: Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.
High Temperature Rating: This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
Flexible Mounting: Includes standard button mounts along with provisions for custom mounting brackets.
Color-Coded Options: Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.
Specifications:
Interfaces/Ports
Network (RJ-45)
Yes
Miscellaneous
Package Contents
PRO4X 36-Outlets PDU
Standard Button Mounts
Management
Management
HTTP/HTTPS
TLSv1.2
SSHv2
Telnet
SNMPv2c
SNMPv3 (GET, SET, Traps)
IPv4
IPv6
LDAPv3/LDAPS
TACACS+
RADIUS
FTP/SFTP
Syslog
RS-232
Remote Outlet Switching
Yes
Physical Characteristics
Height
70"
Width
2.2"
Depth
2.5"
Power Description
Circuit Breaker
Yes
Input Current
30 A
Input Frequency
60 Hz
Power Rating (Watt)
5000 W
Environmental Conditions
Minimum Operating Temperature
32°F (0°C)
Maximum Operating Temperature
140°F (60°C)
Minimum Storage Temperature
-40°F (-40°C)
Maximum Storage Temperature
185°F (85°C)
Minimum Operating Humidity
5%
Maximum Operating Humidity
90%
General Information
Product Type
PDU
Manufacturer Part Number
C4G36RA2CBE2FE2
Manufacturer Website Address
http://www.servertech.com
Manufacturer
Server Technology, Inc
Product Name
PRO4X 36-Outlets PDU
Product Series
PRO4X
Brand Name
Server Technology
Technical Information
Protection Type
Fuse
Circuit Protection
Branch Circuit
Circuit Breaker
Plug/Connector Type
NEMA L6-30P
Receptacle Type
IEC 60320 C13
CX
Environmental Sensors
Temperature
Water
Contact Closure
Air Flow
Humidity
Differential Pressure
Locking Receptacles
RamLock Locking Outlet
Receptacle Detail
12 x IEC 60320 C13
24 x CX
Available to order
Estimated to ship in 5-10 business days
Authorized Server Technology Reseller
Direct from Server Technology - engineering & application support available
Server Technology C4G36RA-2CBE2FE2 PRO4X PDU 208 Volt 36 Outlets 0U
Matrix Price
$3,528.72
MSRP $4,056.00−13%You save $527.28
Loading...
Available to order
Estimated to ship in 5-10 business days
Loading...
Authorized Server Technology Reseller
Direct from Server Technology - engineering & application support available
Loading...
Authorized Server Technology Reseller
Direct from Server Technology - engineering & application support available
Free shipping
Standard ground on this item
Product Category
Power Distribution Units (PDUs)
Platform
PRO4X
Metering and Switching
Switched POPS
Total Outlets
36
Server Technology's PRO4X Switched POPS PDUs run on our state-of-the-art Xerus network interface platform and provide remote access to power, PDU status, input, outlet, and branch current monitoring, and outlet on/off control. The PDU features RamLock, a self-locking mechanism to prevent accidental cord disconnects, and our award-winning HDOT Cx outlets that can be deployed as either a C13 or C19. Switched POPS PDUs are secured with strong configurable password, active directory, 256-bit AES encryption, SSH, SSL, and HTTPS support. SNMP traps provide automated alerts on power and environmental conditions from Legrand's plug-and-play environmental monitoring sensors like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more.
HDOT Cx Outlet: Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
45 Degree Angled Infeed: The angled infeed improves accessibility, provides infeed strain relief, and its bend radius is suitable with 60A rated cords.
Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
Multi-Unit Linking & Cascading: Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
Multi-Color LCD: An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
Hot Swappable Controller: The Controller is the PDU's center of intelligence and housescomputing, display, and connectivity ports.
Power Quality Measurements: Monitor and alert on the power being fed to the PDU for harmonics, voltage dips and swells, crest factor, and more at the outlet or load.
RGB LED Outlet Indicators: RGB LEDs identify an outlet's on/off state, if it's above/below a certain power threshold, or if it's in suspect of a power measurement irregularity.
Waveform Capture: Capture voltage and current waveforms automatically or upon demand.
RamLock Locking Outlets: A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
Environmental Monitoring: Support up to 12 daisy-chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
Per- Inlet Power Sensing: PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
Per-Outlet Power Sensing: POPS® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
Branch Circuit Protection: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
Outlet Control: On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
Alternating-Phase Outlets: Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.
High Temperature Rating: This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
Flexible Mounting: Includes standard button mounts along with provisions for custom mounting brackets.
Color-Coded Options: Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.