PDU - Power Distribution Management
Overview
Rack PDUs from Raritan, Server Technology, APC, Vertiv and Eaton — basic, metered, monitored and switched, 15 A to 60 A, single- and three-phase, in 0U vertical and 1U/2U horizontal formats. Not sure which line fits your rack? Start with our rack PDU sizing guide or compare intelligence tiers across vendors.
Read moreRead less
Filter by input plug, voltage, outlet mix and monitoring level below, or contact us / call (800) 217-8085 with your rack layout and we’ll work through the spec with you. Over 5,000 PDUs, most shipping in 5–10 business days.
How to choose a rack PDU in five questions
- What circuit feeds the rack? Match the PDU’s input to the branch circuit exactly: voltage (120 V, 208 V, 240 V or 400/415 V), single- or three-phase, and breaker rating (15, 20, 30, 50 or 60 A). A 30 A three-phase 208 V feed delivers about 8.6 kW at the 80% continuous-load rating; a 60 A feed about 17.3 kW.
- Which plug? The input plug is set by the circuit — NEMA L5-20P/L5-30P for 120 V, L6-20P/L6-30P for 208/240 V single-phase, L21-30P or L15-30P for three-phase, and IEC 60309 pin-and-sleeve for 50/60 A and 400 V. Filter by input plug below and the wrong ones disappear.
- Which outlets, and how many? Count your equipment cords: C13 for most servers and switches, C19 for high-draw gear such as blade chassis and large storage. Locking outlets stop cords backing out. Choose a PDU with headroom for growth — outlet count is the spec you cannot change later.
- How much visibility do you need? Basic distributes power only. Metered adds a local display of input load so you never trip a breaker. Monitored puts that data on the network. Switched lets you remotely power-cycle individual outlets. Outlet-level metering shows draw per device. See our cross-vendor decoder of intelligence tiers.
- Where does it mount? 0U vertical PDUs mount in the rear of the cabinet and keep rack units free; 1U/2U horizontal units suit shallow or shared racks. Dual-feed (A/B) racks want two PDUs on separate circuits.
The full walkthrough — load calculation, redundancy and environmental sensors — is in the rack PDU sizing and engineering guide. Terms you meet along the way are defined in the PDU feature glossary.
Products
Showing 1 - 24 of 2,303

Chatsworth
Basic eConnect PDU Redundancy Pack E0-1015-CE
MPN: E0-1015-CE

Chatsworth
Monitored eConnect PDU EA-3010W-CE
MPN: EA-3010W-CE

Chatsworth
Monitored eConnect PDU EA-3007W-C
MPN: EA-3007W-C
Power the rack. PDU Guide.
Rack PDUs for data centers, colocation and edge. Start with your load, compare capabilities across vendors, and build the right configuration.

Chatsworth
Metered eConnect PDU E1-2125-C
MPN: E1-2125-C

Chatsworth
Metered eConnect PDU Redundancy Pack E1-2019-CE
MPN: E1-2019-CE

Chatsworth
Basic eConnect PDU Redundancy Pack E0-1125-CE
MPN: E0-1125-CE

Chatsworth
Basic eConnect PDU Redundancy Pack E0-1019-CE
MPN: E0-1019-CE

Chatsworth
Basic eConnect PDU Redundancy Pack E0-1018-CE
MPN: E0-1018-CE

Chatsworth
Switched eConnect PDU EA-5137-E
MPN: EA-5137-E

Chatsworth
Monitored Pro eConnect PDU EA-40C6W-C
MPN: EA-40C6W-C

Chatsworth
Switched Pro eConnect® PDU EA-67F7W-E
MPN: EA-67F7W-E

Chatsworth
Switched Pro eConnect® PDU EA-67F7W-CE
MPN: EA-67F7W-CE

Chatsworth
Switched Pro eConnect PDU EA-67F7W-C
MPN: EA-67F7W-C

Chatsworth
Switched Pro eConnect® PDU EA-67F6W-E
MPN: EA-67F6W-E

Chatsworth
Switched Pro eConnect® PDU EA-67F6W-CE
MPN: EA-67F6W-CE

Chatsworth
Switched Pro eConnect® PDU EA-67F6W-C
MPN: EA-67F6W-C

Chatsworth
Switched Pro eConnect® PDU EA-67F5W-E
MPN: EA-67F5W-E

Chatsworth
Switched Pro eConnect® PDU EA-67F5W-CE
MPN: EA-67F5W-CE

Chatsworth
Switched Pro eConnect® PDU EA-67F5W-C
MPN: EA-67F5W-C

Chatsworth
Switched Pro eConnect® PDU EA-67F4W-E
MPN: EA-67F4W-E

Chatsworth
Switched Pro eConnect® PDU EA-67F4W-CE
MPN: EA-67F4W-CE

Chatsworth
Switched Pro eConnect® PDU EA-67F4W-C
MPN: EA-67F4W-C

Chatsworth
Switched Pro eConnect® PDU EA-67F3W-E
MPN: EA-67F3W-E

Chatsworth
Switched Pro eConnect® PDU EA-67F3W-CE
MPN: EA-67F3W-CE
Showing 1 - 24 of 2,303