Description:
Server Technology's PRO4X Switched PDUs run on our state-of-the-art Xerus network interface platform and provide remote access to power, PDU status, input and branch current monitoring, and outlet on/off control. The PDU features RamLock, a self-locking mechanism to prevent accidental cord disconnects, and our award-winning HDOT Cx outlets that can be deployed as either a C13 or C19. Switched PDUs are secured with strong configurable password, active directory, 256-bit AES encryption, SSH, SSL and HTTPS support. SNMP traps provide automated alerts on power and environmental conditions from Legrand's plug-and-play environmental monitoring sensors like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more.
- HDOT Cx Outlets:
- Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
- 45 Degree Angled Infeed:
- The angled infeed improves accessibility, provides infeed strain relief, and its bend radius is suitable with 60A rated cords.
- Network Monitoring:
- Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
- Multi-Unit Linking & Cascading:
- Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
- Multi-Color LCD:
- An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
- Hot Swappable Controller:
- The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
- Power Quality Measurements:
- Monitor and alert on the power being fed to the PDU for harmonics, voltage dips and swells, crest factor, and more at the outlet or load.
- RGB LED Outlet Indicators:
- RGB LEDs identify an outlet's on/off state, if it's above/below a certain power threshold, or if it's in suspect of a power measurement irregularity.
- Waveform Capture:
- Capture voltage and current waveforms automatically or upon demand.
- RamLock Locking Outlets:
- A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
- Environmental Monitoring:
- Support up to 12 daisy-chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
- Per-Inlet Power Sensing (PIPS®):
- Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
- Branch Circuit Protection:
- This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetichydraulic circuit breakers or UL 248 fuses.
- Outlet Control:
- On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
- Alternating-Phase Outlets:
- Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.
- High Temperature Rating:
- This product has been tested and approved for safe and reliable operation in 60°C data center environments.
- Flexible Mounting:
- Includes standard button mounts along with provisions for custom mounting brackets.
- Color-Coded Options:
- Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.
Specifications:
| Interfaces/Ports | | Network (RJ-45) | Yes | | Management | | Management | - HTTP/HTTPS
- TLSv1.2
- SSHv2
- Telnet
- SNMPv2c
- SNMPv3 (GET, SET, Traps)
- IPv4
- IPv6
- LDAPv3/LDAPS
- TACACS+
- RADIUS
- FTP/SFTP
| | Remote Outlet Switching | Yes | | Miscellaneous | | Certifications & Standards | - ENIEC 62368-1 (TUVR certified, T-mark)
- IEC 62368-1
- EMC
- EN55032 / CISPR 32
- EN55035 / CISPR 35
- EN61000-3-2 / IEC 61000-3-2
- EN61000-3-3 / IEC 61000-3-3
- CE Mark
- 2014/35/EU (Low Voltage Directive)
- 2014/30/EU (EMC Directive)
- UKCA Mark
| | Environmentally Friendly | Yes | | Environmental Compliance | Restriction of Hazardous Substances (RoHS) | | Physical Characteristics | | Height | 80" | | Width | 2.2" | | Depth | 2.5" | | Power Description | | Circuit Breaker | Yes | | Input Current | 32 A | | Input Frequency | 60 Hz | | Power Rating (Watt) | 7300 W | | Environmental Conditions | | Minimum Operating Temperature | 32°F (0°C) |
| | Maximum Operating Temperature | 140°F (60°C) | | Minimum Storage Temperature | -40°F (-40°C) | | Maximum Storage Temperature | 185°F (85°C) | | Minimum Operating Humidity | 5% | | Maximum Operating Humidity | 90% | | General Information | | Product Type | PDU | | Manufacturer Part Number | C4W48RAEPBE2FD7 | | Manufacturer Website Address | http://www.servertech.com | | Manufacturer | Server Technology, Inc | | Product Name | PRO4X 48-Outlets PDU | | Product Series | PRO4X | | Brand Name | Server Technology | | Technical Information | | Features | Multi-color LCD | | Protection Type | Branch Circuit | | Circuit Breaker | | Circuit Protection | | Fuse | | Plug/Connector Type | IEC 2P+PE 6Hr 230V/32A | | Receptacle Type | CX | | IEC 60320 C13 | | Locking Receptacles | RamLock Locking Outlet | | Receptacle Detail | 24 x IEC 60320 C13 | | 24 x CX |
|