Server Technology C4G48RA-DCBE2FD7 PRO4X PDU 208 Volt 48 Outlets 0U

Server Technology

MSRP: $5,306.00 SALE PRICE
$4,510.10

REGULAR PRICE $4,775.40

(You Save $795.90)

MFG#:C4G48RA-DCBE2FD7
Product Category:PDU
Platform:PRO4X
Metering and Switching:Switched POPS

Additional information

Description:

Server Technology's PRO4X Switched PDUs run on our state-of-the-art Xerus network interface platformand provide remote access to power, PDU status, input and branch current monitoring, and outlet on/off control. The PDU features RamLock, a self-locking mechanismto prevent accidental cord disconnects, and our award-winning HDOT Cx outlets that can be deployed as either a C13 or C19. Switched PDUs are secured with strong configurable password, active directory, 256-bit AES encryption, SSH, SSL and HTTPS support. SNMP traps provide automated alerts on power and environmental conditions fromLegrand's plug-and-play environmental monitoring sensors like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more.

  • HDOT Cx Outlets: Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
  • 45 Degree Angled Infeed: The angled infeed improves accessibility, provides infeed strain relief, and its bend radius is suitable with 60A rated cords.
  • Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
  • Multi-Unit Linking & Cascading: Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
  • Multi-Color LCD: An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
  • Hot Swappable Controller: The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
  • Power Quality Measurements: Monitor and alert on the power being fed to the PDU for harmonics, voltage dips and swells, crest factor, and more at the outlet or load.
  • RGB LED Outlet Indicators: RGB LEDs identify an outlet's on/off state, if it's above/below a certain power threshold, or if it's in suspect of a power measurement irregularity.
  • Waveform Capture: Capture voltage and current waveforms automatically or upon demand.
  • RamLock Locking Outlets: A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
  • Environmental Monitoring: Support up to 12 daisy-chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
  • Per-Inlet Power Sensing: PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
  • Branch Circuit Protection: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
  • Outlet Control: On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
  • Alternating-Phase Outlets: Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.
  • High Temperature Rating: This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
  • Flexible Mounting: Includes standard button mounts along with provisions for custom mounting brackets.
  • Color-Coded Options: Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.

Specifications:

Interfaces/Ports
Network (RJ-45)Yes
Management
Management
  • HTTP/HTTPS
  • TLSv1.2
  • SSHv2
  • Telnet
  • SNMPv2c
  • v3 (GET, SET, Traps)
  • IPv4 and IPv6
  • LDAPv3/LDAPS
  • TACACS+
  • RADIUS
  • FTP/SFTP
Remote Outlet SwitchingYes
Miscellaneous
Package Contents
  • PRO4X 48-Outlets PDU
  • Button Mounts
Certifications & Standards

Safety (Listed & Certified, cTUVus mark):

  • UL 62368-1
  • CSA C22.2 No. 62368-1

EMC:

  • FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A
  • CANICES-003, Class A
Physical Characteristics
Height70"
Width2.2"
Depth2.5"
Power Description
Circuit BreakerYes
Input Current30 A
Input Frequency60 Hz
Power Rating (Watt)8600 W
Environmental Conditions
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature140°F (60°C)
Minimum Storage Temperature-40°F (-40°C)
Maximum Storage Temperature185°F (85°C)
Minimum Operating Humidity5%
Maximum Operating Humidity90%
General Information
Product TypePDU
Manufacturer Part NumberC4G48RA-DCBE2FD7
Manufacturer Website Addresshttp://www.servertech.com
ManufacturerServer Technology, Inc
Product NamePRO4X 48-Outlets PDU
Product SeriesPRO4X
Brand NameServer Technology
Technical Information
FeaturesMulti-color LCD
Protection TypeBranch Circuit
Circuit Breaker
Circuit Protection
Fuse
Plug/Connector TypeNEMA L15-30P
PhaseThree Phase
Receptacle TypeCX
IEC 60320 C13
Locking ReceptaclesRamLock Locking Outlet
Receptacle Detail24 x IEC 60320 C13
24 x CX