Server Technology C3S36RL-0AJE2LT4 Smart PRO3X with PIPS 0U 36 RamLock HDOT Outlets

Server Technology

Regular Price $1,867.00
Discount Price: $1,568.00
Shipping:
Free Shipping
Product Overview:

Smart PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/1-Phase (L-L)/20A, Input: IEC C20 100-240V Inlet

MFG#:
C3S36RL-0AJE2LT4
Product Category:
PDU
Adding to cart… The item has been added

Description:

Smart PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/1-Phase (L-L)/20A, Input: IEC C20 100-240V Inlet (Enters From Outlet Face of the PDU, Outlet Number 1 is On the Same End as the Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers, Input Cord (PTCORD-Lx) Ordered Separately

Specifications:

Inputs

Input Voltage (V): 208
Input Plug: NEMA L6-30P
Input Current (A): 30
Input Current Rated (A): 24
Input Power Capacity (kW): 5.0

Outputs

Connector Rating
(18) x IEC 60320/C13 North American Rating: ≤ 12A @208V L-L (15A Peak)
(18) x Cx North American Rating: ≤ 16A @208V L-L (20A Peak)

Branch Circuit Protection

UL489 Compliant 2-pole, 20A trip circuit breakers, two (2) branch, rating: ≤ 16A, 10 kAIC (North America) / (5 kAIC ROW) Interrupt Rating

Physical

Dimensions: 70.0in tall x 2.2in wide x 2.5in deep [1778mm x 56mm x 64mm]

Environmental

Operating Environment: 32°F to 140°F / 0°C to 60°C | 8%RH to 90%RH non-condensing | 6,500ft/2km elevation
Storage Environment: -40°F to 185°F / -40°C to 85°C | 8%RH to 90%RH non-condensing | 50,000ft/15km elevation
Quiescent / Unloaded Power Draw: < 10W for all configurations

Communications & Security

Dual Ethernet, Two (2) 10/100/1000 Mbps (Cat5e/6 connector), Optional WiFi (802.11 a/b/g/n)
One (1) Sensor port (RJ45), One (1) Aux port (6P6C), One (1) Console/Modem port (RJ45), One (1) USB-A and One (1) USB-B
Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP

Certifications

North American:
Safety (Listed & Certified, cTUVus mark)
  • UL 62368-1
  • CSA C22.2 No. 62368-1
EMC
  • FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A
  • CAN ICES-003, Class A

Measurement Accuracy

Input Measurement Accuracy:
LED Current = ± 10% at 0.1 amp (0.3 - 9.9 amps) and 1 amp (> 9.9 amps) resolution
GUI Current = ± 1% at 0.01 amp resolution (above 0.25 amp)
Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%)
Active Power = ± 1% at 1 watt resolution
Apparent Power = ± 1% at 1 volt-amp resolution
Power Factor = ± 3% at 0.01 resolution
Crest Factor = ± 10% at 0.1 resolution
Energy = ± 1% at 0.1 kilowatt-hour resolution

Key Features

  • Hdot cx outlets r4
    HDOT CX OUTLETS
    Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
  • Network monitoring r4
    NETWORK MONITORING
    Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
  • Multi primary linking r4
    MULTI-UNIT LINKING & CASCADING
    Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
  • Multi color lcd r4
    MULTI-COLOR LCD
    An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
  • Hot swappable controller r4
    HOT SWAPPABLE CONTROLLER
    The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
  • Ramlock locking outlets r4
    RAMLOCK LOCKING OUTLETS
    A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
  • Environmental monitoring r4
    ENVIRONMENTAL MONITORING
    Support up to 12 daisy chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
  • Pips per inlet power sensing sti r4
    PER-INLET POWER SENSING
    PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
  • Branch current monitoring r4
    BRANCH CURRENT MONITORING
    Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
  • Branch circuit protection r4
    BRANCH CIRCUIT PROTECTION
    This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
  • High temperature rating r4
    HIGH TEMPERATURE RATING
    This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
  • Flexible mounting r4
    FLEXIBLE MOUNTING
    Includes standard button mounts along with provisions for custom mounting brackets.