Description:
Smart PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/1-Phase (L-L)/20A, Input: IEC C20 100-240V Inlet (Enters From Outlet Face of the PDU, Outlet Number 1 is On the Same End as the Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers, Input Cord (PTCORD-Lx) Ordered Separately
Specifications:
Inputs
Input Voltage (V): | 208 |
Input Plug: | NEMA L6-30P |
Input Current (A): | 30 |
Input Current Rated (A): | 24 |
Input Power Capacity (kW): | 5.0 |
Outputs
Connector | Rating |
---|---|
(18) x IEC 60320/C13 | North American Rating: ≤ 12A @208V L-L (15A Peak) |
(18) x Cx | North American Rating: ≤ 16A @208V L-L (20A Peak) |
Branch Circuit Protection
UL489 Compliant 2-pole, 20A trip circuit breakers, two (2) branch, rating: ≤ 16A, 10 kAIC (North America) / (5 kAIC ROW) Interrupt RatingPhysical
Dimensions: 70.0in tall x 2.2in wide x 2.5in deep [1778mm x 56mm x 64mm]Environmental
Operating Environment: 32°F to 140°F / 0°C to 60°C | 8%RH to 90%RH non-condensing | 6,500ft/2km elevationStorage Environment: -40°F to 185°F / -40°C to 85°C | 8%RH to 90%RH non-condensing | 50,000ft/15km elevation
Quiescent / Unloaded Power Draw: < 10W for all configurations
Communications & Security
Dual Ethernet, Two (2) 10/100/1000 Mbps (Cat5e/6 connector), Optional WiFi (802.11 a/b/g/n)One (1) Sensor port (RJ45), One (1) Aux port (6P6C), One (1) Console/Modem port (RJ45), One (1) USB-A and One (1) USB-B
Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP
Certifications
North American:Safety (Listed & Certified, cTUVus mark)
- UL 62368-1
- CSA C22.2 No. 62368-1
- FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A
- CAN ICES-003, Class A
Measurement Accuracy
Input Measurement Accuracy:LED Current = ± 10% at 0.1 amp (0.3 - 9.9 amps) and 1 amp (> 9.9 amps) resolution
GUI Current = ± 1% at 0.01 amp resolution (above 0.25 amp)
Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%)
Active Power = ± 1% at 1 watt resolution
Apparent Power = ± 1% at 1 volt-amp resolution
Power Factor = ± 3% at 0.01 resolution
Crest Factor = ± 10% at 0.1 resolution
Energy = ± 1% at 0.1 kilowatt-hour resolution
Key Features
-
HDOT CX OUTLETSCx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
-
NETWORK MONITORINGGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
-
MULTI-UNIT LINKING & CASCADINGDaisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
-
MULTI-COLOR LCDAn easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
-
HOT SWAPPABLE CONTROLLERThe Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
-
RAMLOCK LOCKING OUTLETSA mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
-
ENVIRONMENTAL MONITORINGSupport up to 12 daisy chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
-
PER-INLET POWER SENSINGPIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
-
BRANCH CURRENT MONITORINGMonitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
-
BRANCH CIRCUIT PROTECTIONThis PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
-
HIGH TEMPERATURE RATINGThis product has been tested and approved for safe and reliable operation in 60 °C data center environments.
-
FLEXIBLE MOUNTINGIncludes standard button mounts along with provisions for custom mounting brackets.