Server Technology 48DCWC-16-2X100-A0 PRO1 -48VDC Power

Server Technology

Regular Price $3,895.00
Discount Price: $3,311.00
Shipping:
Free Shipping
Product Overview:

PRO1 -48VDC Remote Power Manager, (16) 10A switched outputs w/ Load-Sense, 10A GMT fuses included

MFG#:
48DCWC-16-2X100-A0
Product Category:
PDU
Platform:
PRO1
Metering and Switching:
-48 VDC
Total Outlets:
16
Plug Type:
Terminals
Input Phase:
DC
Power Capacity:
9.6 kW
Input Monitoring:
none
Input Current:
200
Input Current Rating:
200
Form Factor:
2U
Rack Mounting Style:
Horizontal
Branch Monitoring:
None
Alt Phase:
FALSE
Adding to cart… The item has been added

Description:

PRO1 -48VDC Remote Power Manager, (16) 10A switched outputs w/ Load-Sense, 10A GMT fuses included (other values available), dual 100A input blocks, supports two temperature/humidity probes, STI black paint

Specifications:

Inputs

Input Voltage (V): -48
Input Current (A): 200
Input Current Rated (A): 200
Input Power Capacity (kW): 9.6

Outputs

Terminals: (16) x Screw-down terminals (10A max)

Branch Circuit Protection

GMT Fuses Included

Physical

Dimensions: 3.5in tall x 17.0in wide x 12.0in deep [89mm x 432mm x 305mm]

Environmental

Operating Environment: 32°F to 122°F / 0°C to 50°C | 8%RH to 90%RH non-condensing | 6,500ft/2km elevation
Storage Environment: -40°F to 185°F / -40°C to 85°C | 8%RH to 90%RH non-condensing | 50,000ft/15km elevation
Quiescent / Unloaded Power Draw: < 10W for all configurations

Communications & Security

10/100/1000 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector)
Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) - {also on Link PDU}
Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP

Certifications

North American:
Safety (TUVR certified, cTUVus mark)
  • UL Std. 60950-1, 62368-1
  • CAN/CSA-C22.2 No. 60950-1, CAN/CSA-C22.2 No. 62368-1
EMC
  • FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A
  • CAN ICES-003, Class A
Global:
Safety
  • EN 62368-1 (TUVR certified, T-mark)
  • IEC 60950-1 incl. regional, national and harmonized differences (IECEE CB scheme)
  • IEC 62368-1 incl. regional, national and harmonized differences (IECEE CB scheme)
EMC
  • EN 55032 / IEC 55032 / CISPR 32
  • EN 55024 / CISPR 24
  • EN 55035 / IEC 55035 / CISPR 35
  • EN 61000-3-2 / IEC 61000-3-2
  • EN 61000-3-3 / IEC 61000-3-3

  • RoHS, European Hazardous Materials Directive, 2011/65/EU
  • WEEE Compliant
  • CE Mark
  • UK Legislation
  • RoHS, Electrical Equipment (Safety) and Electromagnetic Compatibility

Measurement Accuracy

Input Measurement Accuracy:
LED Current = ± 10% at 0.1 amp (0.5 - 9.9 amps) and 1 amp (> 9.9 amps) resolution
GUI Current = ± 5% at 0.01 amp resolution (above 0.5 amp)