Raritan PX4-532A-E7V2A2 3PH 208V 60A 36 OUTLE

Raritan

Regular Price $3,853.00
Discount Price: $3,159.00
Shipping:
Free Shipping
MFG#:
PX4-532A-E7V2A2
Product Category:
PDU
Adding to cart… The item has been added

Description:

208V, 3-Phase Delta (L-L), 17.3kVA, 48A

Specifications:

Features

    Branch Current Monitoring
Energy Metering

Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor

Metering Accuracy

Class 0.5 meter

Metering per input line

Yes

Metering per Branch Circuit Breaker

Yes

Metering per Output Receptacle

Yes

Remote Outlet Switching

Yes

Power Quality Monitoring

Voltage and Current Harmonic Distortion; Distortion Power Factor; Voltage Dip and Voltage Swell; Neutral Current, Current Inrush, Crest Factor

Outlet Power Distribution

Alternating Branch

Replaceable Controller

Yes, hot-swappable

Environmental Sensor Ready

Yes

Compatible Sensors

Temperature, Humidity, Air Flow, Differential Pressure, Dust/Particle, Water Leak, Proximity/Motion, Vibration, Dry Contact, and Contact Closure.

PDU Linking

Link up to 8 PDUs where the Primary PDU has knowledge and power information from the attached Expansion PDUs. Redundant power from the first expansion unit ensures uptime even if the Primary PDU loses power.

Cascading

Physically cascade 32 PDUs under one ethernet port or 16 PDUs with USB using bridging mode, or additionally, save IP addresses using a single IP address with port forwarding.

Linking

Yes, a maximum of 8 PDUs can be linked using the PDU Link Port; PDU 1 is defined as the Primary PDU and can link up to 7 additional PDUs, called Link PDUs, totaling 8 PDUs.

Networking

(10/100/1000 Base T) Ethernet, Secondary redundant (10/100/1000 Base T) Ethernet. Optional WiFi (802.11 a/b/g/n).

Remote Management

HTTP(s); SSH (CLI); Telnet; RS-232 (Serial); SNMP version v2/v3; SMTP; JSON-RPC API; MODBUS-TCP; Redfish API

Onboard Display

Color, matrix LCD display : Voltage, current, or active power (per line, per breaker, or per receptacle / outlet); Alarms; Configuration information (name, ratings, IP / Networking information). Auto-flip orientation.

Input

Input Plug

208V Delta 60A IEC 60309 3P+G 9Hr

Nominal Voltage

208V

Maximum Input Current

60A

Rated Input Current

48A

Power Capacity

17.3kVA

Cord Length

3m

Output

Nominal Voltage

208 - 240V

Receptacles (Output Connections)

(18) C13, (18) Cx

Overload Protection

6

Physical

Dimensions (WxDxH)

56mm x 65mm x 1780mm

Unit Weight

24 lbs

Shipping Weight

30.2 lbs

Shipping Dimensions

1940x255x125

Mounting

G4-HOLDER-FOR-ZU

Environmental

Operating Temperature/Environment

60 C

Operating Relative Humidity

85%

Operating Elevation

0-6000ft

Conformance

Regulatory Approvals

UL

Warranty

Standard 2 years manufacturer warranty