PDU - Power Distribution Management
Overview
Rack PDUs from Raritan, Server Technology, APC, Vertiv and Eaton — basic, metered, monitored and switched, 15 A to 60 A, single- and three-phase, in 0U vertical and 1U/2U horizontal formats. Not sure which line fits your rack? Start with our rack PDU sizing guide or compare intelligence tiers across vendors.
Read moreRead less
Filter by input plug, voltage, outlet mix and monitoring level below, or contact us / call (800) 217-8085 with your rack layout and we’ll work through the spec with you. Over 5,000 PDUs, most shipping in 5–10 business days.
How to choose a rack PDU in five questions
- What circuit feeds the rack? Match the PDU’s input to the branch circuit exactly: voltage (120 V, 208 V, 240 V or 400/415 V), single- or three-phase, and breaker rating (15, 20, 30, 50 or 60 A). A 30 A three-phase 208 V feed delivers about 8.6 kW at the 80% continuous-load rating; a 60 A feed about 17.3 kW.
- Which plug? The input plug is set by the circuit — NEMA L5-20P/L5-30P for 120 V, L6-20P/L6-30P for 208/240 V single-phase, L21-30P or L15-30P for three-phase, and IEC 60309 pin-and-sleeve for 50/60 A and 400 V. Filter by input plug below and the wrong ones disappear.
- Which outlets, and how many? Count your equipment cords: C13 for most servers and switches, C19 for high-draw gear such as blade chassis and large storage. Locking outlets stop cords backing out. Choose a PDU with headroom for growth — outlet count is the spec you cannot change later.
- How much visibility do you need? Basic distributes power only. Metered adds a local display of input load so you never trip a breaker. Monitored puts that data on the network. Switched lets you remotely power-cycle individual outlets. Outlet-level metering shows draw per device. See our cross-vendor decoder of intelligence tiers.
- Where does it mount? 0U vertical PDUs mount in the rear of the cabinet and keep rack units free; 1U/2U horizontal units suit shallow or shared racks. Dual-feed (A/B) racks want two PDUs on separate circuits.
The full walkthrough — load calculation, redundancy and environmental sensors — is in the rack PDU sizing and engineering guide. Terms you meet along the way are defined in the PDU feature glossary.
Products
Showing 1 - 22 of 22

Server Technology
Server Technology C4W36RA-5BBD2EE1 - Switched 36-Outlet 220/380V 20A
MPN: C4W36RA-5BBD2EE1

Server Technology
Server Technology C4G36RC-GSBD2FAX/Y3 - Switched POPS 36-Outlet 400/415V 3-Phase 60A
MPN: C4G36RC-GSBD2FAX/Y3

Raritan
Raritan PX4-5936I2R-E8V2 - Outlet Metered and Switched 2U 24-Outlet 415V 3-Phase 60A
MPN: PX4-5936I2R-E8V2
Power the rack. PDU Guide.
Rack PDUs for data centers, colocation and edge. Start with your load, compare capabilities across vendors, and build the right configuration.

Raritan
Raritan PX4-56A9I2U-C8E7V2 - Outlet Metered and Switched 0U 48-Outlet 415V 3-Phase 60A
MPN: PX4-56A9I2U-C8E7V2

Raritan
Raritan PX4-56A8I2R-C8E8F5V2 - Outlet Metered and Switched 2U 18-Outlet 415V 3-Phase 60A
MPN: PX4-56A8I2R-C8E8F5V2

Raritan
Raritan PX3-5830I2U-F1V2 PX3 PDU 415 Volt 36 Outlets 0U
MPN: PX3-5830I2U-F1V2

Raritan
Raritan PX3-577AI2U-E2V2 PX3 PDU 415 Volt 30 Outlets 0U
MPN: PX3-577AI2U-E2V2

Raritan
Raritan PX3-5747I2-V2 PX3 PDU 415 Volt 48 Outlets 0U
MPN: PX3-5747I2-V2

Server Technology
Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 220/380V-240/415V
MPN: C4S36RA-5CBD2EE1

Server Technology
Metered, 36 Configurable HDOT Outlets, 415V 3PH Wye 30A L22-30P
MPN: C1M36TS-5CPD2Txxx

Raritan
Raritan PX3-5871I2U-F1N2 3PH 400V AC 60A 48 outlets Zero U
MPN: PX3-5871I2U-F1N2

Raritan
Raritan PX3-5830I2U-V2 3PH 400V AC 60A 36 outlets Zero U
MPN: PX3-5830I2U-V2

Raritan
Raritan PX3-580AI2R-E2 3PH 415V AC 60A 18 outlets 2U
MPN: PX3-580AI2R-E2

Raritan
Raritan PX3-5747V-V2 3PH 415V AC 60A 48 outlets Zero U
MPN: PX3-5747V-V2

Raritan
Raritan PX3-5747T-V2 3PH 415V AC 60A 48 outlets Zero U
MPN: PX3-5747T-V2

Raritan
Raritan PX3-5747U-V2 3PH 415V AC 60A 48 outlets Zero U
MPN: PX3-5747U-V2

Raritan
PX3-5747I2U-V2 3PH 415V AC 60A 48 outlets Zero U
MPN: PX3-5747I2U-V2

Raritan
Raritan PX3-5747I2U-O1V2 3PH 415V AC 60A 48 outlets
MPN: PX3-5747I2U-O1V2

Raritan
Raritan PX3-5363I2-N1V23PH 400V AC 60A 54 outlets Zero U
MPN: PX3-5363I2-N1V2

Raritan
Raritan PX3-5214I2U-V2 3PH 400V AC 60A 54 outlets Zero U
MPN: PX3-5214I2U-V2

Raritan
Raritan PX3-5215I2V-P1V4 3PH 400V AC 60A 21 outlets Zero U
MPN: PX3-5215I2V-P1V4

Raritan
Raritan PX3-5008I2R-Q1 2U horizontal 34.5kVA 18 outlets PDU
MPN: PX3-5008I2R-Q1
Showing 1 - 22 of 22