PDU - Power Distribution Management
Overview
Rack PDUs from Raritan, Server Technology, APC, Vertiv and Eaton — basic, metered, monitored and switched, 15 A to 60 A, single- and three-phase, in 0U vertical and 1U/2U horizontal formats. Not sure which line fits your rack? Start with our rack PDU sizing guide or compare intelligence tiers across vendors.
Read moreRead less
Filter by input plug, voltage, outlet mix and monitoring level below, or contact us / call (800) 217-8085 with your rack layout and we’ll work through the spec with you. Over 5,000 PDUs, most shipping in 5–10 business days.
How to choose a rack PDU in five questions
- What circuit feeds the rack? Match the PDU’s input to the branch circuit exactly: voltage (120 V, 208 V, 240 V or 400/415 V), single- or three-phase, and breaker rating (15, 20, 30, 50 or 60 A). A 30 A three-phase 208 V feed delivers about 8.6 kW at the 80% continuous-load rating; a 60 A feed about 17.3 kW.
- Which plug? The input plug is set by the circuit — NEMA L5-20P/L5-30P for 120 V, L6-20P/L6-30P for 208/240 V single-phase, L21-30P or L15-30P for three-phase, and IEC 60309 pin-and-sleeve for 50/60 A and 400 V. Filter by input plug below and the wrong ones disappear.
- Which outlets, and how many? Count your equipment cords: C13 for most servers and switches, C19 for high-draw gear such as blade chassis and large storage. Locking outlets stop cords backing out. Choose a PDU with headroom for growth — outlet count is the spec you cannot change later.
- How much visibility do you need? Basic distributes power only. Metered adds a local display of input load so you never trip a breaker. Monitored puts that data on the network. Switched lets you remotely power-cycle individual outlets. Outlet-level metering shows draw per device. See our cross-vendor decoder of intelligence tiers.
- Where does it mount? 0U vertical PDUs mount in the rear of the cabinet and keep rack units free; 1U/2U horizontal units suit shallow or shared racks. Dual-feed (A/B) racks want two PDUs on separate circuits.
The full walkthrough — load calculation, redundancy and environmental sensors — is in the rack PDU sizing and engineering guide. Terms you meet along the way are defined in the PDU feature glossary.
Products
Showing 1 - 24 of 121

Server Technology
Server Technology SEV-4523D - Switched 0U 48-Outlet 240/415V 30A
MPN: SEV-4523D

Server Technology
Server Technology C1W24VT-5PPA17AC power distribution unit (PDU) 24 AC outlet(s) 0U Black
MPN: C1W24VT-5PPA17AC

Server Technology
Server Technology C4W48RA-5CBD2ED3 - Switched 48-Outlet 220/380V 30A
MPN: C4W48RA-5CBD2ED3
Power the rack. PDU Guide.
Rack PDUs for data centers, colocation and edge. Start with your load, compare capabilities across vendors, and build the right configuration.

Server Technology
Server Technology C4W36RA-GPBD2EE1 - Switched 36-Outlet 400/415V 3-Phase 30A
MPN: C4W36RA-GPBD2EE1

Server Technology
Server Technology C4W36RA-5CBD2FE1 PRO4X PDU 415 Volt 36 Outlets 0U
MPN: C4W36RA-5CBD2FE1

Server Technology
Server Technology C4W36RA-5CBD2EE1 - Switched 36-Outlet 220/380V 30A
MPN: C4W36RA-5CBD2EE1

Server Technology
Server Technology C4T48RA-5CBD2FD3 - Smart POPS 48-Outlet 220/380V 30A
MPN: C4T48RA-5CBD2FD3

Server Technology
Server Technology C4T48RA-5CBD2ED3 - Smart POPS 48-Outlet 220/380V 30A
MPN: C4T48RA-5CBD2ED3

Server Technology
Server Technology C4T36RA-5CBD2FE1 PRO4X PDU 415 Volt 36 Outlets 0U
MPN: C4T36RA-5CBD2FE1

Server Technology
Server Technology C3W36RL-5CJE2NT2 - Switched 0U 36-Outlet 415V 3-Phase 30A
MPN: C3W36RL-5CJE2NT2

Server Technology
Server Technology C3W36RL-5CJE2LT2 - Switched 0U 36-Outlet 415V 3-Phase 30A
MPN: C3W36RL-5CJE2LT2

Server Technology
Server Technology C3W36RL-52JE2MT2 - Switched 0U 36-Outlet 415V 3-Phase 30A
MPN: C3W36RL-52JE2MT2

Server Technology
Server Technology C1X24VT-5CPA15AC - Switched 0U 24-Outlet 240/415V 30A
MPN: C1X24VT-5CPA15AC

Server Technology
Server Technology C1X24VT-5CPA17AC - Switched 0U 24-Outlet 240/415V 30A
MPN: C1X24VT-5CPA17AC

Server Technology
Server Technology SEV-4523Z - Switched 0U 48-Outlet 240/415V 30A
MPN: SEV-4523Z

Server Technology
Server Technology C3W36RL-5CJE29T2 - Switched 0U 36-Outlet 415V 3-Phase 30A
MPN: C3W36RL-5CJE29T2

Server Technology
Server Technology C1W24VT-5CPA15AC PRO1 PDU 415 Volt 24 Outlets 0U
MPN: C1W24VT-5CPA15AC

Server Technology
Server Technology C1W24VT-5CPA17AC PRO1 PDU 415 Volt 24 Outlets 0U
MPN: C1W24VT-5CPA17AC

Server Technology
Server Technology C2W42CE-5CAE2M00 PRO2 PDU 415 Volt 42 Outlets 0U
MPN: C2W42CE-5CAE2M00

Server Technology
Server Technology C2SG48TE-5CAE2M99 PRO2 PDU 415 Volt 48 Outlets 0U
MPN: C2SG48TE-5CAE2M99

Server Technology
Server Technology C2SG36TE-5CAE2M66 PRO2 PDU 415 Volt 36 Outlets 0U
MPN: C2SG36TE-5CAE2M66

Raritan
Raritan PX4-2630I2R-C8E8 - PDU Metered and Switched 2U 24-Outlet 415V 3-Phase 30A
MPN: PX4-2630I2R-C8E8

Server Technology
Server Technology C4T36RA-5CBD2EE1 - Smart POPS 36-Outlet 220/380V 30A
MPN: C4T36RA-5CBD2EE1

Server Technology
Server Technology C4S36RA-GPBD2EE1/30R2 - Smart 36-Outlet 400/415V 3-Phase 30A
MPN: C4S36RA-GPBD2EE1/30R2
Showing 1 - 24 of 121

