PDU - Power Distribution Management
Overview
Rack PDUs from Raritan, Server Technology, APC, Vertiv and Eaton — basic, metered, monitored and switched, 15 A to 60 A, single- and three-phase, in 0U vertical and 1U/2U horizontal formats. Not sure which line fits your rack? Start with our rack PDU sizing guide or compare intelligence tiers across vendors.
Read moreRead less
Filter by input plug, voltage, outlet mix and monitoring level below, or contact us / call (800) 217-8085 with your rack layout and we’ll work through the spec with you. Over 5,000 PDUs, most shipping in 5–10 business days.
How to choose a rack PDU in five questions
- What circuit feeds the rack? Match the PDU’s input to the branch circuit exactly: voltage (120 V, 208 V, 240 V or 400/415 V), single- or three-phase, and breaker rating (15, 20, 30, 50 or 60 A). A 30 A three-phase 208 V feed delivers about 8.6 kW at the 80% continuous-load rating; a 60 A feed about 17.3 kW.
- Which plug? The input plug is set by the circuit — NEMA L5-20P/L5-30P for 120 V, L6-20P/L6-30P for 208/240 V single-phase, L21-30P or L15-30P for three-phase, and IEC 60309 pin-and-sleeve for 50/60 A and 400 V. Filter by input plug below and the wrong ones disappear.
- Which outlets, and how many? Count your equipment cords: C13 for most servers and switches, C19 for high-draw gear such as blade chassis and large storage. Locking outlets stop cords backing out. Choose a PDU with headroom for growth — outlet count is the spec you cannot change later.
- How much visibility do you need? Basic distributes power only. Metered adds a local display of input load so you never trip a breaker. Monitored puts that data on the network. Switched lets you remotely power-cycle individual outlets. Outlet-level metering shows draw per device. See our cross-vendor decoder of intelligence tiers.
- Where does it mount? 0U vertical PDUs mount in the rear of the cabinet and keep rack units free; 1U/2U horizontal units suit shallow or shared racks. Dual-feed (A/B) racks want two PDUs on separate circuits.
The full walkthrough — load calculation, redundancy and environmental sensors — is in the rack PDU sizing and engineering guide. Terms you meet along the way are defined in the PDU feature glossary.
Products
Showing 1 - 24 of 335

Tripp Lite
Eaton 3-Phase Managed RACK PDU G4, 208V, 42 Outlets, 48A, 17.3KW, 460P9W Input, EVMA4609X
MPN: EVMA4609X

Tripp Lite
Eaton 3-Phase Managed RACK PDU G4, 208V, 42 Outlets, 48A, 17.3KW, 460P9W Input, EVMA4609X-06
MPN: EVMA4609X-06

Tripp Lite
Eaton 3-Phase Metered Input RACK PDU G4, 208V, 42 Outlets, 48A, 17.3KW, 460P9W I EVMI4609X
MPN: EVMI4609X
Power the rack. PDU Guide.
Rack PDUs for data centers, colocation and edge. Start with your load, compare capabilities across vendors, and build the right configuration.

Tripp Lite
Eaton 3-Phase Metered Input RACK PDU G4, 208V, 42 Outlets, 48A, 17.3KW, 460P9W I EVMI4609X-06
MPN: EVMI4609X-06

Server Technology
Server Technology C4T36RA-DQBD2EE1 - Smart POPS 36-Outlet 208-240V 60A
MPN: C4T36RA-DQBD2EE1

Server Technology
Server Technology C4W48RA-DQBD2ED3 - Switched 48-Outlet 208-240V 60A
MPN: C4W48RA-DQBD2ED3

Server Technology
Server Technology C4W36RA-YQBD2EE1 - Switched 36-Outlet 120/208V 60A
MPN: C4W36RA-YQBD2EE1

Server Technology
Server Technology C4W36RA-YBBE2EE3 - Switched 36-Outlet 120/208V 20A
MPN: C4W36RA-YBBE2EE3

Server Technology
Server Technology C4T48RA-DQBD2FD3 - Smart POPS 48-Outlet 208-240V 60A
MPN: C4T48RA-DQBD2FD3

Server Technology
Server Technology C4T48RA-DQBD2ED3 - Smart POPS 48-Outlet 208-240V 60A
MPN: C4T48RA-DQBD2ED3

Server Technology
Server Technology C4T36RA-YQBD2FE1/Z1 - Smart POPS 36-Outlet 120/208V 60A
MPN: C4T36RA-YQBD2FE1/Z1

Server Technology
Server Technology C4T36RA-YQBD2EE1 - Smart POPS 36-Outlet 120/208V 60A
MPN: C4T36RA-YQBD2EE1

Server Technology
Server Technology C4T36RA-YQBD2FE1 PRO4X PDU 208 Volt 36 Outlets 0U
MPN: C4T36RA-YQBD2FE1

Server Technology
Server Technology C3W36RL-YQJE29T2 - Switched 0U 36-Outlet 208V 3-Phase 60A
MPN: C3W36RL-YQJE29T2

Server Technology
Server Technology C3W36RL-DQJE2NT2 - Switched 0U 36-Outlet 208V 3-Phase 60A
MPN: C3W36RL-DQJE2NT2

Server Technology
Server Technology C3W36RL-DQJE29T2 - Switched 0U 36-Outlet 208V 3-Phase 60A
MPN: C3W36RL-DQJE29T2

Server Technology
Switched Master PRO2 (42) Configurable Alt Phase Hdot Outlets, 208V 3PH Wye 6BR C2W42CE-YQME2M00
MPN: C2W42CE-YQME2M00

Server Technology
Server Technology C3W36RL-DQJE2LT2 - Switched 0U 36-Outlet 208V 3-Phase 60A
MPN: C3W36RL-DQJE2LT2

Server Technology
Server Technology C3W36RL-YQJE2NT2 - Switched 0U 36-Outlet 208V 3-Phase 60A
MPN: C3W36RL-YQJE2NT2

Server Technology
Server Technology C3W36RL-YQJE2LT2 - Switched 0U 36-Outlet 208V 3-Phase 60A
MPN: C3W36RL-YQJE2LT2

Server Technology
Server Technology C4W48RA-YQBD2ED3 - Switched 48-Outlet 120/208V 60A
MPN: C4W48RA-YQBD2ED3

Server Technology
Server Technology C2W54CE-YQME2M00 PRO2 PDU 208 Volt 54 Outlets 0U
MPN: C2W54CE-YQME2M00

Server Technology
Server Technology C2SG48TE-YQME2M99 PRO2 PDU 208 Volt 48 Outlets 0U
MPN: C2SG48TE-YQME2M99

Server Technology
Server Technology C2SG48TE-DQME2M99 PRO2 PDU 208 Volt 48 Outlets 0U
MPN: C2SG48TE-DQME2M99
Showing 1 - 24 of 335

