PDU - Power Distribution Management
Overview
Rack PDUs from Raritan, Server Technology, APC, Vertiv and Eaton — basic, metered, monitored and switched, 15 A to 60 A, single- and three-phase, in 0U vertical and 1U/2U horizontal formats. Not sure which line fits your rack? Start with our rack PDU sizing guide or compare intelligence tiers across vendors.
Read moreRead less
Filter by input plug, voltage, outlet mix and monitoring level below, or contact us / call (800) 217-8085 with your rack layout and we’ll work through the spec with you. Over 5,000 PDUs, most shipping in 5–10 business days.
How to choose a rack PDU in five questions
- What circuit feeds the rack? Match the PDU’s input to the branch circuit exactly: voltage (120 V, 208 V, 240 V or 400/415 V), single- or three-phase, and breaker rating (15, 20, 30, 50 or 60 A). A 30 A three-phase 208 V feed delivers about 8.6 kW at the 80% continuous-load rating; a 60 A feed about 17.3 kW.
- Which plug? The input plug is set by the circuit — NEMA L5-20P/L5-30P for 120 V, L6-20P/L6-30P for 208/240 V single-phase, L21-30P or L15-30P for three-phase, and IEC 60309 pin-and-sleeve for 50/60 A and 400 V. Filter by input plug below and the wrong ones disappear.
- Which outlets, and how many? Count your equipment cords: C13 for most servers and switches, C19 for high-draw gear such as blade chassis and large storage. Locking outlets stop cords backing out. Choose a PDU with headroom for growth — outlet count is the spec you cannot change later.
- How much visibility do you need? Basic distributes power only. Metered adds a local display of input load so you never trip a breaker. Monitored puts that data on the network. Switched lets you remotely power-cycle individual outlets. Outlet-level metering shows draw per device. See our cross-vendor decoder of intelligence tiers.
- Where does it mount? 0U vertical PDUs mount in the rear of the cabinet and keep rack units free; 1U/2U horizontal units suit shallow or shared racks. Dual-feed (A/B) racks want two PDUs on separate circuits.
The full walkthrough — load calculation, redundancy and environmental sensors — is in the rack PDU sizing and engineering guide. Terms you meet along the way are defined in the PDU feature glossary.
Products
Showing 1 - 24 of 390

Server Technology
Server Technology C3W36RL-DCJE2NT3 - Switched 0U 36-Outlet 208V 3-Phase 30A
MPN: C3W36RL-DCJE2NT3

Tripp Lite
Eaton 3-Phase Managed RACK PDU G4, 208V, 24 Outlets, 24A, 8.6KW, L15-30 Input, 1 EVMA1530A
MPN: EVMA1530A

Tripp Lite
Eaton 3-Phase Managed RACK PDU G4, 208V, 42 Outlets, 24A, 8.6KW, L15-30 Input, 1 EVMA1530X
MPN: EVMA1530X
Power the rack. PDU Guide.
Rack PDUs for data centers, colocation and edge. Start with your load, compare capabilities across vendors, and build the right configuration.

Tripp Lite
Eaton 3-Phase Managed RACK PDU G4, 120/208V, 24 Outlets, 24A, 8.6KW, L21-30 INPU EVMA2130A
MPN: EVMA2130A

Tripp Lite
Eaton 3-Phase Managed RACK PDU G4, 120/208V, 42 Outlets, 24A, 8.6KW, L21-30 INPU EVMA2130X
MPN: EVMA2130X

Tripp Lite
Eaton 3-Phase Metered Input RACK PDU G4, 208V, 42 Outlets, 24A, 8.6KW, L15-30 in EVMI1530X
MPN: EVMI1530X

Tripp Lite
Eaton 3-Phase Metered Input RACK PDU G4, 120/208V, 42 Outlets, 24A, 8.6KW, L21-3 EVMI2130X
MPN: EVMI2130X

Server Technology
Server Technology C4G48RA-YCBE2FD8/30G2 - Switched POPS 48-Outlet 120/208V 30A
MPN: C4G48RA-YCBE2FD8/30G2

Server Technology
Server Technology C4W48RA-DCBE2ED7 - Switched 48-Outlet 208-240V 30A
MPN: C4W48RA-DCBE2ED7

Server Technology
Server Technology C4W36RA-DCBE2EE2 - Switched 36-Outlet 208-240V 30A
MPN: C4W36RA-DCBE2EE2

Server Technology
Server Technology C4T48RA-DCBE2FD7 - Smart POPS 48-Outlet 208-240V 30A
MPN: C4T48RA-DCBE2FD7

Server Technology
Server Technology C4T48RA-DCBE2ED7 - Smart POPS 48-Outlet 208-240V 30A
MPN: C4T48RA-DCBE2ED7

Server Technology
Server Technology C4W36RA-DCBE2FE2 PRO4X PDU 208 Volt 36 Outlets 0U
MPN: C4W36RA-DCBE2FE2

Server Technology
Server Technology C3W36RL-YCJE2LT3 - Switched 0U 36-Outlet 208V 3-Phase 30A
MPN: C3W36RL-YCJE2LT3

Server Technology
Server Technology C3W36RL-YCJE29T3 - Switched 0U 36-Outlet 208V 3-Phase 30A
MPN: C3W36RL-YCJE29T3

Server Technology
Server Technology C3W36RL-YCJE2NT3 - Switched 0U 36-Outlet 208V 3-Phase 30A
MPN: C3W36RL-YCJE2NT3

Server Technology
Server Technology C3W36RL-DCJE2LT3 - Switched 0U 36-Outlet 208V 3-Phase 30A
MPN: C3W36RL-DCJE2LT3

Server Technology
Server Technology C3W36RL-DCJE29T3 - Switched 0U 36-Outlet 208V 3-Phase 30A
MPN: C3W36RL-DCJE29T3

Server Technology
Server Technology C4W48RA-YCBE2ED8 - Switched 48-Outlet 120/208V 30A
MPN: C4W48RA-YCBE2ED8

Server Technology
Server Technology C3WG36RL-YCJE29T3 - Switched POPS 0U 36-Outlet 208V 3-Phase 30A
MPN: C3WG36RL-YCJE29T3

Server Technology
Server Technology C1W24VS-YCFA13C9 PRO1 PDU 208 Volt 24 Outlets 0U
MPN: C1W24VS-YCFA13C9

Server Technology
Server Technology C1W24VS-YCFA11C9 PRO1 PDU 208 Volt 24 Outlets 0U
MPN: C1W24VS-YCFA11C9

Server Technology
Server Technology C1W24VS-DCFA11A1 PRO1 PDU 208 Volt 24 Outlets 0U
MPN: C1W24VS-DCFA11A1

Server Technology
Server Technology C1W24VS-DCFA13A1 PRO1 PDU 208 Volt 24 Outlets 0U
MPN: C1W24VS-DCFA13A1
Showing 1 - 24 of 390