Rack PDUs from Raritan, Server Technology, APC, Vertiv and Eaton — basic, metered, monitored and switched, 15 A to 60 A, single- and three-phase, in 0U vertical and 1U/2U horizontal formats. Not sure which line fits your rack? Start with our rack PDU sizing guide or compare intelligence tiers across vendors.
Read moreRead less
Filter by input plug, voltage, outlet mix and monitoring level below, or contact us / call (800) 217-8085 with your rack layout and we’ll work through the spec with you. Over 5,000 PDUs, most shipping in 5–10 business days.
How to choose a rack PDU in five questions
- What circuit feeds the rack? Match the PDU’s input to the branch circuit exactly: voltage (120 V, 208 V, 240 V or 400/415 V), single- or three-phase, and breaker rating (15, 20, 30, 50 or 60 A). A 30 A three-phase 208 V feed delivers about 8.6 kW at the 80% continuous-load rating; a 60 A feed about 17.3 kW.
- Which plug? The input plug is set by the circuit — NEMA L5-20P/L5-30P for 120 V, L6-20P/L6-30P for 208/240 V single-phase, L21-30P or L15-30P for three-phase, and IEC 60309 pin-and-sleeve for 50/60 A and 400 V. Filter by input plug below and the wrong ones disappear.
- Which outlets, and how many? Count your equipment cords: C13 for most servers and switches, C19 for high-draw gear such as blade chassis and large storage. Locking outlets stop cords backing out. Choose a PDU with headroom for growth — outlet count is the spec you cannot change later.
- How much visibility do you need? Basic distributes power only. Metered adds a local display of input load so you never trip a breaker. Monitored puts that data on the network. Switched lets you remotely power-cycle individual outlets. Outlet-level metering shows draw per device. See our cross-vendor decoder of intelligence tiers.
- Where does it mount? 0U vertical PDUs mount in the rear of the cabinet and keep rack units free; 1U/2U horizontal units suit shallow or shared racks. Dual-feed (A/B) racks want two PDUs on separate circuits.
The full walkthrough — load calculation, redundancy and environmental sensors — is in the rack PDU sizing and engineering guide. Terms you meet along the way are defined in the PDU feature glossary.
Products
Showing 1 - 24 of 261

Tripp Lite
PDUMNV30HV2LX - Power Distribution UNIT - Vertical (0U) - 208/230V - 5.5KW - (36 PDUMNV30HV2LX
MPN: PDUMNV30HV2LX

Tripp Lite
PDUMNV30HVLX - Power Distribution UNIT - Vertical (0U) - 208/230V - 5.5KW - (20) PDUMNV30HVLX
MPN: PDUMNV30HVLX

Tripp Lite
PDUMNV30LX - Power Distribution UNIT - Vertical (0U) - 120V - 2.9KW - (24) 5-15/ PDUMNV30LX
MPN: PDUMNV30LX
Power the rack. PDU Guide.
Rack PDUs for data centers, colocation and edge. Start with your load, compare capabilities across vendors, and build the right configuration.

Tripp Lite
PDUMV15 - Power Distribution UNIT - Vertical (0U) - 120V - 1.44KW - (16) 5-15R - PDUMV15
MPN: PDUMV15

Tripp Lite
PDUMV15-24 - Power Distribution UNIT - Vertical (0U) - 100-127V - 1.52KW - (8) 5 PDUMV15-24
MPN: PDUMV15-24

Tripp Lite
PDUMV15-36 - Power Distribution UNIT - Vertical (0U) - 100-127V - 1.52KW - (14) PDUMV15-36
MPN: PDUMV15-36

Tripp Lite
Eaton Tripp LITE Series 1.5KW 100-127V Single-Phase Local Metered PDU - 36 NEMA PDUMV15-72
MPN: PDUMV15-72

Tripp Lite
PDUMV15-ISO - Power Distribution UNIT - Vertical (0U) - 120V - 1.44KW - (16) 5-1 PDUMV15-ISO
MPN: PDUMV15-ISO

Tripp Lite
Eaton 1.4KW Single-Phase Switched PDU - LX Interface, 120V Outlets (16 5-15R), 1 PDUMV15NETLX
MPN: PDUMV15NETLX

Tripp Lite
PDUMV20 - Power Distribution UNIT - Vertical (0U) - 120V - 1.92KW - (28) 5-15/20 PDUMV20
MPN: PDUMV20

Tripp Lite
Eaton Tripp LITE Series 2KW Single-Phase Local Metered PDU, 100-127V Outlets (6 PDUMV20-24
MPN: PDUMV20-24

Tripp Lite
Eaton Tripp LITE Series 2KW Single-Phase Local Metered PDU, 100-127V Outlets (14 PDUMV20-36
MPN: PDUMV20-36

Tripp Lite
Eaton Tripp LITE Series 2KW Single-Phase Local Metered PDU, 100-127V Outlets (36 PDUMV20-72
MPN: PDUMV20-72

Tripp Lite
1.92KW Single-Phase Local Metered PDU WITH Isobar Surge Protection 120V 3840 JOU PDUMV20-ISO
MPN: PDUMV20-ISO

Tripp Lite
Eaton Tripp LITE Series 3.7KW Single-Phase Local Metered PDU, 208/230V Outlets ( PDUMV20HV
MPN: PDUMV20HV

Tripp Lite
Eaton Tripp LITE Series 3.7KW 208/230V Single-Phase Local Metered PDU - 16 C13 & PDUMV20HV-36
MPN: PDUMV20HV-36

Tripp Lite
Eaton 3.7KW Single-Phase Switched PDU - LX Interface, 208/230V Outlets (20 C13 & PDUMV20HVNETLX
MPN: PDUMV20HVNETLX

Tripp Lite
Eaton 1.9KW Single-Phase Switched PDU - LX Interface, 120V Outlets (24 5-15/20R) PDUMV20NETLX
MPN: PDUMV20NETLX

Tripp Lite
Eaton Tripp LITE Series 2.9KW Single-Phase Local Metered PDU, 120V Outlets (24 5 PDUMV30
MPN: PDUMV30

Tripp Lite
2.88KW Single-Phase Local Metered PDU WITH Isobar Surge Protection 120V 3840 JOU PDUMV30-ISO
MPN: PDUMV30-ISO

Tripp Lite
Eaton Tripp LITE Series 5.5KW Single-Phase Local Metered PDU, 208/230V Outlets ( PDUMV30HV
MPN: PDUMV30HV

Tripp Lite
PDUMV30HV2 - Eaton Tripp LITE Series 5.8KW Single-Phase Local Metered PDU, 200-2 PDUMV30HV2
MPN: PDUMV30HV2

Tripp Lite
Eaton 5.5KW Single-Phase Switched PDU - LX Interface, 208/230V Outlets (20 C13 & PDUMV30HVNETLX
MPN: PDUMV30HVNETLX

Tripp Lite
Eaton 2.9KW Single-Phase Switched PDU - LX Interface, 120V Outlets (24 5-15/20R) PDUMV30NETLX
MPN: PDUMV30NETLX
Showing 1 - 24 of 261