Raritan DPXR8-15

Availability: In stock

Regular Price: $649.00

Special Price: $538.67

Quick Overview

1PH, 120V AC, 15A (12A Rated) 8 Outlets: NEMA 5-15R Plug: NEMA 5-15P, 1.4kVA, 1U Horizontal PDU, Ethernet, Serial and Sensor Connections

PX8-15

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

  • PX8-15

Details

The PX series offers hundreds of models to meet all your data center applications including models with outlet switching, individual outlet metering, high power for blade servers and high-density applications and 400 volt power distribution.

Raritan power management solutions help data center and facilities managers accomplish the following activities:

  • Make informed capacity planning decisions
  • Efficiently utilize power resources
  • Improve uptime and staff productivity
  • Save power and money
  • Measure PUE and drive green data center initiatives

With PX, real-time, accurate power monitoring and metering is now available down to the individual outlets that servers plug into. Not only does PX provide active and apparent power but it also accurately measures and tracks energy usage (kWH), provides remote switching of outlets and alerts upon preset power and environment events. In addition to reliable distribution of power, all PXs are environment monitoring ready to accept Raritan's plug-and-play environment probes and sensors.

To find the switch that best fits your needs, see the tables below.  

Outlet Metered, Outlet Switched

VAC Outlets Rack Units Amps Per Phase
16 20 30 32 50 60
120 8 1 DPXR8-15
DPCR8-15-J
DPXR8-20
DPXR8-20L
PX-5812
       
120 12 Zero DPXS12-15 DPXS12-20
DPXS12-20L
DPCS12-20L-J
DPCS12-30L
DPXS12-30L
DPCS12-30L-J
     
120 20 Zero   DPCS20-20
DPXS20-20
DPXS20-20L
DPXS20-20L-J
DPXS20-30L
DPCS20-30L-J
     
120 20 2   DPXR20-20
DPXR20-20L
DPXR20-30L      
120 24 Zero   PX-5802T        
3PH
120/
208
24 Zero     PX-5652      
3PH
120/
208
30 Zero            
208 6 2     PX-5810      
208 8 1   DPXR8A-20L6
DPCR8A-20L6-J
PX-5198      
208 16 Zero     PX-5384      
208 20 Zero   DPXS20A-20L6 DPCS20A-30L6
DPXS20A-30L6
DPXS20A-30L6-J
PX-5464
PX-5464T
     
208 20 2    DPXR20A-20L6 DPXR20A-30L6      
208 24 Zero     PX-5496      
230 8 1 DPXR8A-16     PX-5170     
230 12 Zero DPXS12A-16     DPXS12A-32
PX-5297
   
230 16 Zero PX-5367     PX-5397    
230 20 Zero DPXS20A-16
DPXS20A-16AU-M
   

DPXS20A-32
PX-5469T, PX-5469
PX-5469A2T

   
230 20 2 DPXR20A-16     DPXR20A-32    
230 24 Zero DPXS24A-16T          

240

8 1 DPXR8A-15AU  DPXR8A-20AU        
240 12 Zero   DPXS12A-20AU   DPXS12A-32AUA    
240 16 Zero       PX-5820
PX-5820A1
PX-5820A2
   
240 20 Zero   DPXS20A-20AU   DPXS20A-32AUA, PX-5469A2T    
240 24 Zero   PX-5635   PX-5501    
3PH 208 6 2     PX-5119      
3PH
208
18 Zero     PX-5902T
PX-5924
     
3PH
208
24 Zero   PX-5508, PX-5510 PX-5520
PX-5522, PX-5523
PX-5524
PX-5525
  PX-5532
PX-5534
PX-5535
 
3PH
230
12 2U           PX-5301
3PH
230
24 Zero           PX-5551
3PH
400
12 Zero PX-5314
PX-5315
  PX-5616 PX-5318
PX-5318A2
   
3PH
400
12 2       PX-5341    
3PH
400
18 Zero       PX-5906T    
3PH
400
24 Zero PX-5628I   PX-5630
PX-5633

PX-5528
PX-5530
PX-5917
PX-5917A1
PX-5917A2

   
3PH 400 36 Zero     PX2-5704U      

 

Outlet Metered

VAC Outlets Rack
Units
Amps Per Phase
20 30 32 50 60
208 8 1U   PX-4198      
208 16 Zero   PX-4384      
208 24 Zero   PX-4496      
3PH
208
6 Zero      

PX-4100
PX-4322

PX-4102
3PH
208
12 Zero       PX-4316 PX-4320
3PH
208
24 Zero   PX-4520
PX-4522
PX-4523
PX-4524
PX-4525
  PX-4532
PX-4534
PX-4535
 
3PH
230
24 Zero         PX-4551
3PH
230
12 2U         PX-4301
3PH
240
16 Zero     PX-4820
PX-4820A1
PX-4820A2
   
3PH
400
6 Zero   PX-4120  PX-4104
PX-4104A1
PX-4104A2
   
3PH
400
12 Zero   PX-4621
PX-4633
PX-4307
PX-4530
   
3PH 400 18 Zero     PX2-4507    
3PH 400 18 2U       PX2-4913U  
3PH
400
24 Zero   PX-4630

PX-4530
PX-4917
PX-4917A1
PX-4917A2

   
3PH 400 36 Zero     PX2-4704U    

 

Inline Meters

VAC Lines Rack
Units
Amps Per Phase
16 20 30 32 50 60
100-240 2 1U PX-3211
PX-3220
PX-3211
PX-3220
PX-3220 PX-3220    
100-240 4 1U PX-3411
PX-3420
DPXR4X1A-16NP
PX-3411
PX-3420
PX-3420 PX-3420    
3PH 190 - 415 2 1U     PX-3270 PX-3270    
3PH 190 - 415 3 1U     PX-3370 PX-3370    

Note 1: PX-3211 and PX-3411 operate at either 16A or 20A depending on the cord set chosen.
Note 2: PX-3220 and PX-3420 operate at up to 40A (32A rated) per line depending on the wiring in the data center.

Features Benefits
Power Distribution
Power Sequencing
(User Defined)
In the event the PX is reset, the outlets will be turned on in a user-defined sequence at user-defined intervals to prevent tripping circuit breakers due to in-rush currents. (Applies only to PX models that support switching.)
Receptacle Status Retention In the event of a power outage, power is restored only to those receptacles that were on before the outage. For PX models that don't support switching, power will be restored to all outlets.
Circuit Breakers The PX uses UL 489 circuit breakers instead of fuses in 30A/32A models or higher, meeting the newest safety standard for branch circuit protection (UL60950 third edition). This eliminates the need for spare fuses and the time to replace them. Also, in many cases, a certified/licensed electrician is required to replace a fuse, whereas circuit breakers can be reset by a user.
Power Monitoring
Power Metering The PX enables users to measure power at the outlet level (RMS, apparent power), providing an accurate view of power consumption at both a server or PDU level.
Alerting In case a threshold is exceeded, or a circuit breaker trips, the PX alerts the user via e-mail, SMS (via external gateway), audio alarm, and SNMP TRAPs, providing advanced warning before major incidents occur.
Overload Alarm User-configurable current threshold provides audible and visual alarm on current overload, allowing the user to act immediately to prevent potential burnouts and interruption of services.
Environmental Monitoring The PX supports external optional but fully integrated temperature and humidity sensors, providing early warning about hotspots or changes in cooling.
Seven-Segment LED Display Shows actual current, voltage and circuit breaker status of the PDU for both the total strip and for individual receptacles.
Remote Access
IP Auto Configuration with DHCP, BOOTP Easy setup and administration.
Flexible Remote Access Options Users can access the PX through a variety of access protocols for switching (where supported), metering, data collection and monitoring:
  • Convenient HTML GUI
  • Server Management Interface (IPMI)
  • Network Management Interface (SNMP)
  • UNIX®-like console interface via serial connector or TELNET/SSH (compatible with SMASH server management)
Dynamic DNS Support Users can access the PX over a connection with a dynamically assigned IP address - which corresponds to a single DNS name.
IPMI and SMASH CLP The first and only PDU in the world that supports industry management standards: the Intelligent Platform Management Interface (IPMI) and the Distributed Management Task Force's (DMTF) Systems Management Architecture for Server Hardware (SMASH) CLP, providing a uniform way to manage both servers and the PDU.
Power Management
HTML User Interface The PX's intuitive browser-based GUI enables remote energy management.
Outlet Grouping When using PX models which support switching in a stand-alone mode over TCP/IP, users can define multiple outlets across multiple PDUs to function as a single virtual outlet. This is useful for powering down and rebooting servers with redundant power supplies.
Virtual Outlets For PX models that support switching, outlets on multiple PX units can be grouped for ease of management and administration of servers.
Integration with Multiple Raritan Solutions Simplified power control capabilities, power on/off/recycle, is available through Raritan's Dominion KXII, Dominion SX, Paragon® II, and CommandCenter® Secure Gateway 3.1.1 or higher, providing systems administrators access to power control via one­user interface.
Security
Up to 256-bit AES Encryption The PX is the first and only PDU in the industry that supports 256-bit AES encryption.
SSL Certificate Creating individual server side SSL certificates enhances the security level of PX.
Event Logging Tracks user logins, logouts, and power activities for an audit trail to support regulatory compliance.
Local and Remote Authentication and Authorization PX provides built-in support for standards-based authentication protocols, including LDAP/S, RADIUS, and Active Directory. When deployed in conjunction with other Raritan solutions, additional authentication schemes can be supported, including TACACS+, Kerberos, and SecureID.
User-Rights Per Outlet An administrator can assign permissions on an outlet level to prevent unauthorized access.
Hardware Features
Vertical and Horizontal Rack Mount Models PX units come in a choice of space-saving form factors for vertical and horizontal rack mounting. 1U and 2U units mount horizontally on standard racks. Zero U units mount vertically on rack frames.
Integration with Industry-Leading Racks Easy integration and support for up to 5 different mounting positions in industry-leading racks.
Connections Serial RJ-12 for environmental probes, RJ-45 for serial access/Power-CIM, RJ-45 Ethernet 10/100Base-T. Link status, network activity, and 10/100 status LED. Full support for full-duplex and 100Mbps operation.
Receptacle Status LED Individual LED indicator at each receptacle allow for quick and easy status checks at the rack.
Flexibility of Connections Simultaneous connection via Ethernet (TCP/IP) and serial ports for advanced applications and redundancy of connections.