Details
The PX series offers hundreds of models to meet all your data center applications including models with outlet switching, individual outlet metering, high power for blade servers and high-density applications and 400 volt power distribution.
Raritan power management solutions help data center and facilities managers accomplish the following activities:
- Make informed capacity planning decisions
- Efficiently utilize power resources
- Improve uptime and staff productivity
- Save power and money
- Measure PUE and drive green data center initiatives
With PX, real-time, accurate power monitoring and metering is now available down to the individual outlets that servers plug into. Not only does PX provide active and apparent power but it also accurately measures and tracks energy usage (kWH), provides remote switching of outlets and alerts upon preset power and environment events. In addition to reliable distribution of power, all PXs are environment monitoring ready to accept Raritan's plug-and-play environment probes and sensors.
To find the switch that best fits your needs, see the tables below.
Outlet Metered, Outlet Switched
| VAC | Outlets | Rack Units | Amps Per Phase | |||||
| 16 | 20 | 30 | 32 | 50 | 60 | |||
| 120 | 8 | 1 | DPXR8-15 DPCR8-15-J |
DPXR8-20 DPXR8-20L PX-5812 |
||||
| 120 | 12 | Zero | DPXS12-15 | DPXS12-20 DPXS12-20L DPCS12-20L-J |
DPCS12-30L DPXS12-30L DPCS12-30L-J |
|||
| 120 | 20 | Zero | DPCS20-20 DPXS20-20 DPXS20-20L DPXS20-20L-J |
DPXS20-30L DPCS20-30L-J |
||||
| 120 | 20 | 2 | DPXR20-20 DPXR20-20L |
DPXR20-30L | ||||
| 120 | 24 | Zero | PX-5802T | |||||
| 3PH 120/ 208 |
24 | Zero | PX-5652 | |||||
| 3PH 120/ 208 |
30 | Zero | ||||||
| 208 | 6 | 2 | PX-5810 | |||||
| 208 | 8 | 1 | DPXR8A-20L6 DPCR8A-20L6-J |
PX-5198 | ||||
| 208 | 16 | Zero | PX-5384 | |||||
| 208 | 20 | Zero | DPXS20A-20L6 | DPCS20A-30L6 DPXS20A-30L6 DPXS20A-30L6-J PX-5464 PX-5464T |
||||
| 208 | 20 | 2 | DPXR20A-20L6 | DPXR20A-30L6 | ||||
| 208 | 24 | Zero | PX-5496 | |||||
| 230 | 8 | 1 | DPXR8A-16 | PX-5170 | ||||
| 230 | 12 | Zero | DPXS12A-16 | DPXS12A-32 PX-5297 |
||||
| 230 | 16 | Zero | PX-5367 | PX-5397 | ||||
| 230 | 20 | Zero | DPXS20A-16 DPXS20A-16AU-M |
DPXS20A-32 |
||||
| 230 | 20 | 2 | DPXR20A-16 | DPXR20A-32 | ||||
| 230 | 24 | Zero | DPXS24A-16T | |||||
|
240 |
8 | 1 | DPXR8A-15AU | DPXR8A-20AU | ||||
| 240 | 12 | Zero | DPXS12A-20AU | DPXS12A-32AUA | ||||
| 240 | 16 | Zero | PX-5820 PX-5820A1 PX-5820A2 |
|||||
| 240 | 20 | Zero | DPXS20A-20AU | DPXS20A-32AUA, PX-5469A2T | ||||
| 240 | 24 | Zero | PX-5635 | PX-5501 | ||||
| 3PH 208 | 6 | 2 | PX-5119 | |||||
| 3PH 208 |
18 | Zero | PX-5902T PX-5924 |
|||||
| 3PH 208 |
24 | Zero | PX-5508, PX-5510 | PX-5520 PX-5522, PX-5523 PX-5524 PX-5525 |
PX-5532 PX-5534 PX-5535 |
|||
| 3PH 230 |
12 | 2U | PX-5301 | |||||
| 3PH 230 |
24 | Zero | PX-5551 | |||||
| 3PH 400 |
12 | Zero | PX-5314 PX-5315 |
PX-5616 | PX-5318 PX-5318A2 |
|||
| 3PH 400 |
12 | 2 | PX-5341 | |||||
| 3PH 400 |
18 | Zero | PX-5906T | |||||
| 3PH 400 |
24 | Zero | PX-5628I | PX-5630 PX-5633 |
PX-5528 |
|||
| 3PH 400 | 36 | Zero | PX2-5704U | |||||
Outlet Metered
| VAC | Outlets | Rack Units |
Amps Per Phase | ||||
| 20 | 30 | 32 | 50 | 60 | |||
| 208 | 8 | 1U | PX-4198 | ||||
| 208 | 16 | Zero | PX-4384 | ||||
| 208 | 24 | Zero | PX-4496 | ||||
| 3PH 208 |
6 | Zero |
PX-4100 |
PX-4102 | |||
| 3PH 208 |
12 | Zero | PX-4316 | PX-4320 | |||
| 3PH 208 |
24 | Zero | PX-4520 PX-4522 PX-4523 PX-4524 PX-4525 |
PX-4532 PX-4534 PX-4535 |
|||
| 3PH 230 |
24 | Zero | PX-4551 | ||||
| 3PH 230 |
12 | 2U | PX-4301 | ||||
| 3PH 240 |
16 | Zero | PX-4820 PX-4820A1 PX-4820A2 |
||||
| 3PH 400 |
6 | Zero | PX-4120 | PX-4104 PX-4104A1 PX-4104A2 |
|||
| 3PH 400 |
12 | Zero | PX-4621 PX-4633 |
PX-4307 PX-4530 |
|||
| 3PH 400 | 18 | Zero | PX2-4507 | ||||
| 3PH 400 | 18 | 2U | PX2-4913U | ||||
| 3PH 400 |
24 | Zero | PX-4630 |
PX-4530 |
|||
| 3PH 400 | 36 | Zero | PX2-4704U | ||||
Inline Meters
| VAC | Lines | Rack Units |
Amps Per Phase | |||||
| 16 | 20 | 30 | 32 | 50 | 60 | |||
| 100-240 | 2 | 1U | PX-3211 PX-3220 |
PX-3211 PX-3220 |
PX-3220 | PX-3220 | ||
| 100-240 | 4 | 1U | PX-3411 PX-3420 DPXR4X1A-16NP |
PX-3411 PX-3420 |
PX-3420 | PX-3420 | ||
| 3PH 190 - 415 | 2 | 1U | PX-3270 | PX-3270 | ||||
| 3PH 190 - 415 | 3 | 1U | PX-3370 | PX-3370 | ||||
Note 1: PX-3211 and PX-3411 operate at either 16A or 20A depending on the cord set chosen.
Note 2: PX-3220 and PX-3420 operate at up to 40A (32A rated) per line depending on the wiring in the data center.
| Features | Benefits |
| Power Distribution | |
| Power Sequencing (User Defined) |
In the event the PX is reset, the outlets will be turned on in a user-defined sequence at user-defined intervals to prevent tripping circuit breakers due to in-rush currents. (Applies only to PX models that support switching.) |
| Receptacle Status Retention | In the event of a power outage, power is restored only to those receptacles that were on before the outage. For PX models that don't support switching, power will be restored to all outlets. |
| Circuit Breakers | The PX uses UL 489 circuit breakers instead of fuses in 30A/32A models or higher, meeting the newest safety standard for branch circuit protection (UL60950 third edition). This eliminates the need for spare fuses and the time to replace them. Also, in many cases, a certified/licensed electrician is required to replace a fuse, whereas circuit breakers can be reset by a user. |
| Power Monitoring | |
| Power Metering | The PX enables users to measure power at the outlet level (RMS, apparent power), providing an accurate view of power consumption at both a server or PDU level. |
| Alerting | In case a threshold is exceeded, or a circuit breaker trips, the PX alerts the user via e-mail, SMS (via external gateway), audio alarm, and SNMP TRAPs, providing advanced warning before major incidents occur. |
| Overload Alarm | User-configurable current threshold provides audible and visual alarm on current overload, allowing the user to act immediately to prevent potential burnouts and interruption of services. |
| Environmental Monitoring | The PX supports external optional but fully integrated temperature and humidity sensors, providing early warning about hotspots or changes in cooling. |
| Seven-Segment LED Display | Shows actual current, voltage and circuit breaker status of the PDU for both the total strip and for individual receptacles. |
| Remote Access | |
| IP Auto Configuration with DHCP, BOOTP | Easy setup and administration. |
| Flexible Remote Access Options | Users can access the PX through a variety of access protocols for switching (where supported), metering, data collection and monitoring:
|
| Dynamic DNS Support | Users can access the PX over a connection with a dynamically assigned IP address - which corresponds to a single DNS name. |
| IPMI and SMASH CLP | The first and only PDU in the world that supports industry management standards: the Intelligent Platform Management Interface (IPMI) and the Distributed Management Task Force's (DMTF) Systems Management Architecture for Server Hardware (SMASH) CLP, providing a uniform way to manage both servers and the PDU. |
| Power Management | |
| HTML User Interface | The PX's intuitive browser-based GUI enables remote energy management. |
| Outlet Grouping | When using PX models which support switching in a stand-alone mode over TCP/IP, users can define multiple outlets across multiple PDUs to function as a single virtual outlet. This is useful for powering down and rebooting servers with redundant power supplies. |
| Virtual Outlets | For PX models that support switching, outlets on multiple PX units can be grouped for ease of management and administration of servers. |
| Integration with Multiple Raritan Solutions | Simplified power control capabilities, power on/off/recycle, is available through Raritan's Dominion KXII, Dominion SX, Paragon® II, and CommandCenter® Secure Gateway 3.1.1 or higher, providing systems administrators access to power control via oneuser interface. |
| Security | |
| Up to 256-bit AES Encryption | The PX is the first and only PDU in the industry that supports 256-bit AES encryption. |
| SSL Certificate | Creating individual server side SSL certificates enhances the security level of PX. |
| Event Logging | Tracks user logins, logouts, and power activities for an audit trail to support regulatory compliance. |
| Local and Remote Authentication and Authorization | PX provides built-in support for standards-based authentication protocols, including LDAP/S, RADIUS, and Active Directory. When deployed in conjunction with other Raritan solutions, additional authentication schemes can be supported, including TACACS+, Kerberos, and SecureID. |
| User-Rights Per Outlet | An administrator can assign permissions on an outlet level to prevent unauthorized access. |
| Hardware Features | |
| Vertical and Horizontal Rack Mount Models | PX units come in a choice of space-saving form factors for vertical and horizontal rack mounting. 1U and 2U units mount horizontally on standard racks. Zero U units mount vertically on rack frames. |
| Integration with Industry-Leading Racks | Easy integration and support for up to 5 different mounting positions in industry-leading racks. |
| Connections | Serial RJ-12 for environmental probes, RJ-45 for serial access/Power-CIM, RJ-45 Ethernet 10/100Base-T. Link status, network activity, and 10/100 status LED. Full support for full-duplex and 100Mbps operation. |
| Receptacle Status LED | Individual LED indicator at each receptacle allow for quick and easy status checks at the rack. |
| Flexibility of Connections | Simultaneous connection via Ethernet (TCP/IP) and serial ports for advanced applications and redundancy of connections. |